GRP floor systems
Overview of anti-slip certificates
| Classification | Grating type | Surface |
Bar (mm) |
Mesh spacing (mm) |
|---|---|---|---|---|
| R10 | moulded type |
smooth surface (GS) | 5/7 |
37 x 38 40 x 40 |
| R10 | moulded type |
smooth surface (GS) | 5/7 | 20 x 20 |
| R10 | moulded high load type |
smooth surface (GS) | 9/11 | 38 x 38 |
| R10 | safety flooring moulded | surface teardrop solo(STS) | / | Closed |
| R11 | safety flooring moulded | surface teardrop quintett (STQ) | / | Closed |
| R11 | moulded type |
concave (K) | 5/7 | 13 x 13 |
| R11 | moulded type |
concave (K) | 5/7 | 20 x 20 |
| R13 | moulded type |
Quartz gritted (QB) | 5/7 | 13 x 13 |
| R13 | moulded type |
Corundum gritted (KB) | 5/7 |
38 x 38 40 x 40 |
| R13 | moulded type |
concave (K) |
5/7 6/8 |
38 x 38 40 x 40 |
| R13 | moulded type |
Quartz gritted (QB) | 5/7 | 20 x 20 |
| R13 | moulded type |
Corundum gritted (KB) | 5/7 | 20 x 20 |
| R13 | moulded type |
Corundum gritted (KB) | 9/11 | 38 x 38 |
| R13 | moulded type |
concave (K) | 6/8 | 50 x 50 |
| R13 | moulded type |
Corundum gritted (KB) | 6/8 | 50 x 50 |
| R13 |
Safety floor cast |
Quartz gritted (QB) | – | Closed |
| R13 |
Cast safety floor |
Corundum gritted (QB) | – | Closed |
| R13 | Profile grating |
Corundum gritted (KB) | 15 (I-bar) | 38 x 152 |
Testing Device
As testing equipment (see figure), a flat, torsion-resistant plate of 600 mm width and 2000 mm length is used, the slope of which can be adjusted from 0 to 45° in the longitudinal direction.
The lifting speed of the drive produces an angular speed of the plate of 1° per second maximum, that is, at least 45 seconds are needed to pass through the total angle of 45°.
The lifting movement can be controlled by the testing personnel either continuously or in stages of 0.5°. An angle-measuring unit which is connected to the testing equipment indicates the angle of inclination of the plate with respect to the horizontal to 0.5° ± 0.2°.
Platforms are fitted to the longitudinal sides of the testing equipment for the safety of the testing personnel.[Extract from BGR 181 and GUV-R 181]